I128-MICRO - 128 Channel Integrating Electrometer

The I128-MICRO is a compact, high-performance integrating electrometer designed for applications requiring precise, simultaneous charge measurement across many channels. With 128 parallel integrators in a device that fits in the palm of a hand, it offers a unique combination of scale, speed, and precision.

Engineered for compatibility with multi-layer Faraday cups, segmented detectors, and pixelated arrays, the I128-MICRO supports high-rate data acquisition with selectable integration frequencies and flexible charge ranges. Its integrated real-time operating system and network-based API make it ideal for automated systems and modern control architectures.

The small form factor and fully parallel architecture enable streamlined deployment in space-constrained environments without compromising data quality. The I128-MICRO represents a new class of electrometer technology for scientific and industrial systems requiring dense, synchronized charge measurement.

12 Tuần Thời Gian Dẫn Đầu

Features

  • 128 fully parallel charge integrators.
  • Dynamic range up to 1.5 µA or 350 pC for 128 channels.
  • From 1 to 6,000 Hz simultaneous sample data rate.
  • Extremely compact form factor.
  • External conversion synchronization BNC connector.
  • Ethernet interface with web server UI and JSON API.

Applications

  • Multi-layer Faraday cup readout.
  • Multi-strip and pixelated detector readout.

Gói Phần Mềm Hiện Đại

  • Dựa vào Hệ điều hành thời gian thực QNX để có hiệu suất và ổn định tuyệt vời
  • Thu thập dữ liệu và kiểm soát đáng tin cậy với API JSON HTTP/Websocket
  • Nhập/xuất toàn diện thông qua máy chủ EPICS nhúng, mạnh mẽ
  • Giao diện người dùng trang web tiên tiến để trực quan hóa dữ liệu và cấu hình
  • Khả năng phát hiện mạng nâng cao bằng cách sử dụng Universal Plug and Play

Made for MLFC

The I128-MICRO was purpose-built for use with Pyramid’s multi-layer Faraday cup (MLFC), delivering unmatched performance for measuring beam charge depth distributions. Its extremely low noise and ultra-sensitive current integration enable precise, high-resolution profiling of ion beams across all MLFC layers simultaneously. This level of measurement fidelity provides critical insights into beam energy deposition, supporting advanced accelerator tuning and research applications.

Sẵn Sàng cho FLASH

Liệu pháp Flash đứng như một bước đột phá trong liệu pháp bức xạ. Cam kết của chúng tôi tập trung vào việc cung cấp các dụng cụ liệu pháp Flash tiên tiến, tập trung vào nghiên cứu, ưu tiên khả năng tiếp cận và thúc đẩy sự hợp tác trong ngành.

Để nhận hướng dẫn từ chuyên gia và cơ hội hợp tác trong các nỗ lực liệu pháp bức xạ sắp tới, hãy liên hệ với đội ngũ kỹ sư và bán hàng tận tâm của chúng tôi ngay hôm nay.

Related Products